{"product_id":"new-fullstandsystem-liquide-prozesse-digitaler-zwilling-nexatwin-simulation-validierung-fur-rockwell-siemens-nexaswift","title":"Surveying system – Digital Twin (NexaTwin) | Simulation \u0026 Validation | NexaSwift","description":"\u003cp\u003eThis \u003cstrong\u003etraining twin\u003c\/strong\u003e replicates a practical \u003cstrong\u003econveying and handling system\u003c\/strong\u003e and is ideally suited for \u003cstrong\u003etraining\u003c\/strong\u003e , \u003cstrong\u003evirtual commissioning\u003c\/strong\u003e , \u003cstrong\u003ediagnostics\u003c\/strong\u003e , and \u003cstrong\u003ePLC programming\u003c\/strong\u003e with \u003cstrong\u003eSiemens S7-1500\u003c\/strong\u003e , \u003cstrong\u003ePLCSIM Advanced\u003c\/strong\u003e , and \u003cstrong\u003eNexaTwin\u003c\/strong\u003e . You train realistically on a complete model – with drive technology, pneumatics, conveyor lines, portal handling, and workpiece carrier data handling via \u003cstrong\u003eRFID\u003c\/strong\u003e .\u003c\/p\u003e\n\u003cp style=\"opacity: .9;\"\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e An \u003cstrong\u003eS7-1500 with PLCSIM Advanced\u003c\/strong\u003e is required for operation. \u003cstrong\u003ePLCSIM Advanced and NexaTwin\u003c\/strong\u003e must run on \u003cstrong\u003ethe same system\u003c\/strong\u003e ( \u003cstrong\u003eshared memory\u003c\/strong\u003e ). Use the \u003cstrong\u003evariable tables\u003c\/strong\u003e specified in the documentation or the supplied \u003cstrong\u003etemplate project\u003c\/strong\u003e (configured PLC including variable table).\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical requirements (operating conditions)\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eSiemens S7-1500\u003c\/strong\u003e in conjunction with \u003cstrong\u003ePLCSIM Advanced\u003c\/strong\u003e (1500 series simulation)\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePLCSIM Advanced\u003c\/strong\u003e and \u003cstrong\u003eNexaTwin\u003c\/strong\u003e on \u003cstrong\u003ethe same system\u003c\/strong\u003e (shared memory)\u003c\/li\u003e\n\u003cli\u003eUsing the predefined \u003cstrong\u003evariable tables\u003c\/strong\u003e (or using the \u003cstrong\u003etemplate project\u003c\/strong\u003e )\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eIncluded functional units \u0026amp; technologies\u003c\/h2\u003e\n\u003cp style=\"opacity: .9;\"\u003eThe training twin covers typical automation tasks – with clearly structured variable logic, diagnostic options and practical error patterns.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eConveyor system\u003c\/strong\u003e as Siemens \u003cstrong\u003eS120 technology object “Velocity Axis”\u003c\/strong\u003e (Telegram 1)\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eLifting table cylinder\u003c\/strong\u003e with \u003cstrong\u003e3 fixed end positions\u003c\/strong\u003e (5\/3-way valve, double-acting)\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eBinary controlled conveyor belts\u003c\/strong\u003e (start\/stop, interlocks, fault\/release concepts)\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePneumatic stopper\u003c\/strong\u003e (2\/2-way valve, single-acting)\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAxle portal\u003c\/strong\u003e with \u003cstrong\u003e3 axes\u003c\/strong\u003e (Telegram 111)\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eVacuum gripper\u003c\/strong\u003e with \u003cstrong\u003eanalog feedback\u003c\/strong\u003e of the actual vacuum value\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRFID\u003c\/strong\u003e read\/write heads for \u003cstrong\u003eworkpiece carrier data handling\u003c\/strong\u003e (WT tracking, identification, process data)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eLearning objectives \u0026amp; typical training content\u003c\/h2\u003e\n\u003ch3\u003eSystem \u0026amp; Project Structure\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStructured setup and safe start \u003cstrong\u003eof a TIA project\u003c\/strong\u003e for S7-1500 + PLCSIM Advanced\u003c\/li\u003e\n\u003cli\u003eUse \u003cstrong\u003evariable tables\u003c\/strong\u003e correctly (addressing, consistency, signal flow) \u0026amp; recognize error patterns\u003c\/li\u003e\n\u003cli\u003eSetting up and checking \u003cstrong\u003ethe PLCSIM Advanced ↔ NexaTwin\u003c\/strong\u003e coupling (Shared Memory)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDrive and axle technology (S120 \/ Technology objects)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCommissioning, enabling and operating technology objects (Velocity Axis, portal axes)\u003c\/li\u003e\n\u003cli\u003eInterpreting \u003cstrong\u003eTelegram 1\u003c\/strong\u003e and \u003cstrong\u003eTelegram 111\u003c\/strong\u003e in Diagnosis \u0026amp; Behavior\u003c\/li\u003e\n\u003cli\u003eCleanly program and test movement sequences, releases, interlocks and error responses.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePneumatics \u0026amp; Peripherals\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSafely control pneumatic actuators (5\/3 double-acting, 2\/2 single-acting) including protection\/locking conditions\u003c\/li\u003e\n\u003cli\u003eRobust implementation of lifting table positioning to three end positions (sequences, state machines)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConveyor technology \u0026amp; process logic\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperate conveyor lines in binary mode and lock them in a process-reliable manner (jams, stopper logic, release chains)\u003c\/li\u003e\n\u003cli\u003eBuild processes as \u003cstrong\u003estep sequences\/state models\u003c\/strong\u003e and debug them systematically.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSensors, analog values \u0026amp; data handling\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eScale\/evaluate analog feedback (actual vacuum value) and use it for process decisions.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRFID data\u003c\/strong\u003e reading\/writing for workpiece carrier tracking (identification, consistency, error cases)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommissioning, diagnostics \u0026amp; troubleshooting\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDiagnosing typical malfunctions (missing release, end position not reached, telegram\/drive error, sensor error)\u003c\/li\u003e\n\u003cli\u003eSystematically check and optimize using observation tables\/variable lists, trace\/watch and status displays.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eBenefits for you\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003ePractical training\u003c\/strong\u003e on a realistic conveying and handling system instead of isolated individual exercises\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFaster onboarding\u003c\/strong\u003e through structured variable concepts, clear signal flows and reproducible scenarios\u003c\/li\u003e\n\u003cli\u003eDevelop \u003cstrong\u003ediagnostic competence\u003c\/strong\u003e : reliably identify and correct typical error patterns\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eTransfer to real-world projects\u003c\/strong\u003e : Technology objects, interlocks, step sequences and data handling as in practice\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e","brand":"NexaSwift","offers":[{"title":"industry \/ Unlimited","offer_id":57149501964665,"sku":null,"price":629.99,"currency_code":"EUR","in_stock":true},{"title":"Education \/ Unlimited","offer_id":57149502030201,"sku":null,"price":59.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0954\/1074\/9817\/files\/Liquide_Prozesse_Mainbild_819dcbe2-95ee-446c-a952-bfee6b378011.png?v=1778224490","url":"https:\/\/nexaswift.de\/en\/products\/new-fullstandsystem-liquide-prozesse-digitaler-zwilling-nexatwin-simulation-validierung-fur-rockwell-siemens-nexaswift","provider":"NexaSwift","version":"1.0","type":"link"}